Time is money, so our systems are faster.

See how much you’ll save with a Web Techniques Rewind System.

Calculate Your ROI
Your equipment is great! We’ll continue to use your products as long as we are in business. Your employees and management are very talented, innovative and helpful. We appreciate your company and the ideas that you put forth.
I’ve had a good experience with the hardware and is a well-built machine that has served it’s time well. It is a workhorse for the ways we use it and keeps our reconciliation honest.
Web Techniques was valuable in helping us select the right table top for the kind of work we are doing. The machine came in on time and worked just as advertised. Follow up service was just as good. We are completely satisfied with our Web Techniques rewinder.
At Clinical Systems we utilize Web Techniques equipment every day. The components they provide to us serve a vital role within our manufacturing process and help us maintain our productivity.
See More Customer Testimonials

SAFETY WARNING: BEFORE PERFORMING ANY REPAIR TO WEB TECHNIQUES EQUIPMENT, YOU MUST TURN OFF THE POWER AND DISCONNECT THE EQUIPMENT FROM THE POWER SOURCE.

Reed Switch Failures

  • On older WT-25 machines, when the reed switches may begin to fail, the customer more than likely needs to replace the old counter circuit board along with the reed switches. This may be due to the old board causing the reed switches to fail. The older board can weaken over time and excessive use, which can result in less voltage output for the switches which in turn could polymerize the tips of the reed switches and cause them to stick. The newest revision circuit board has a higher voltage and can help prevent this condition. The customer needs to replace their old style board because it is wearing out. "It is not a defect, but a wear issue.”
  • Check the connectors to make sure they are tight and that the wires have not been pulled loose inside the connector.

Reed Switch Troubleshooting

  • When troubleshooting a reed switch for length counting, one way to check it on the WT-25 is by locating the pair of LED Lights on the counter circuit board, DS1 and DS2. These are always on except when the magnet on the bottom of the Counter Drive Roll passes over the corresponding switch. The two led lights are always on except when the magnet on the bottom of the counter drive is over the top of the reed switches in the table.
  • The counting direction is determined by which light comes on first after both of them are off. There has to be a period where both lights are off in either sequence (or direction) in order for the process to operate successfully.